berg - die Energieoptimierer

Showing 17–32 of 40 results



  • UBN309 6A B RS   Item number: 003355 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Four-quadrant measurement energy
    Limit value monitoring
    Output: 2x digital
    RAM: 1 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A transformer measurement, 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC
    Communication: RS485 (Modbus RTU) + 2DO


  • UBN309 6A E LAN   Item number: 003356 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    output: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A Wandlermessung, 2-,3- oder 4-Leiternetze, 3×10/17…3×285/495VAC
    Communication: RJ45 – LAN (Mobbus TCP) + 2 DO


  • UBN309 6A E RS   Item number: 003354 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A transformer measurement, 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC
    Communication: RS485 (Modbus RTU) + 2DO
  • UBN309 6A E RS AO   Item number: Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 2x digital, 1x analog
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A Wandlermessung, 2-,3- oder 4-Leiternetze, 3×10/17…3×285/495VAC
    Communication: RJ45 – LAN (Mobbus TCP) + 2DO


  • UBN309 6A E RS AO   Item number: 004072 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 2x digital, 1x analog
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A Wandlermessung, 2-,3- oder 4-Leiternetze, 3×10/17…3×285/495VAC
    Communication: RJ45 – LAN (Mobbus TCP) + 2DO


  • UBN309 RGW30 E LAN 3M   Item number: 003365 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    output: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 30cm
    Communication: Modbus TCP


  • UBN309 RGW30 E RS 3M   Item number: 003364 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 30cm
    Communication: RS485 (Modbus RTU) + 2DO


  • UBN309 RGW30 E RS AO 3M   Item number: 004197 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 30cm
    Communication: RJ45 – LAN (Mobbus TCP) + 2 DO + 1 AO


  • UBN309 RGW45 E LAN 3M   Item number: 003367 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 45cm
    Communication: Modbus TCP


  • UBN309 RGW70 E LAN 3M   Item number: 003368 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 70cm
    Communication: Modbus TCP


  • UBN309 RGW90 E LAN 3M   Item number: 004123 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 90cm
    Communication: Modbus TCP


  • UBN40 6A LAN   Item number: 003307 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection networks: 1/5A, 2-,3- or 4-wire networks, 3×10/17 …3×285/495 VAC
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 6A RS   Item number: 003306 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection Networks: 1/5A, 2-,3- or 4-wire networks, 3×10/17 …3×285/495 VAC
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 80A LAN   Item number: 003302 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection Networks: 2x 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, 80A
    Communication: RJ45 – LAN (Mobbus TCP)


  • UBN40 80A RS   Item number: 003301 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, 80A
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 RGW KIT30 LAN 3M   Item number: 003315 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 30cm
    Communication: RJ45 – LAN (Mobbus TCP)

Fragen Sie uns!
Unser zuständiger Ansprechpartner ruft Sie gern zurück und beantwortet Ihre Fragen. Bitte wählen Sie einen Themenbereich, zu dem Sie ganz individuell beraten werden möchten.
Für die Verarbeitung Ihrer personenbezogenen Daten gilt unsere Datenschutzerklärung.
Just Ask Us
Our responsible contact person will be happy to call you back and answer your questions. Please select a subject area on which you would like to receive individual advice.
The processing of your personal data is governed by our Datenschutzerklärung.