Network Analyzers

Basic Monitoring with Power Analyzers

UBN 309/UBN 309 Rogowski Kit

The UBN 309 is a modern and innovative device for measurement and storage as well as consumption analysis of energy values. By using classic current transformers or connection via flexible Rogowski coils, the UBN 309 offers a wide range of measurement possibilities. The UBN 309 kit includes suitable Rogowski coils.

Thanks to various data interfaces (Modbus RTU/TCP) and an integrated Web server, it can be optimally integrated into existing systems or read remotely via Web interface. The device is suitable for the following areas of application: energy audits, energy and load management, and network and machine monitoring.

Features

  • DIN 96 × 96 mm front door installation
  • Very shallow installation depth of just 3.9 cm
  • Memory for MIN/MAX/AVG
  • 1…5 A transducer measurement
  • Flexible measurement via Rogowski coils (option)
  • Bi-directional four-quadrant measurement
  • Measurement up to 15th harmonic (ENH version)
  • Measurement in 1-, 3-, or 4-wire network
  • Two digital outputs, one digital input
  • Optional: Modbus RTU or Modbus TCP
  • Integrated HTTP Web server (TCP version)

Technical data

Voltage 230 V AC ±15% (RS485) 2.7 V AC
  (115 V AC on request)
  85…265 V AC (Ethernet) 5.8 V AC
Max. consumption (per phase) Max. 0.15 V AC
Frequency 50/60 Hz
Voltage range 600 V AC max. L-L
   
Current range A) 1(5) A transformer measurement
  B) Flexible Rogowski measurement (scaling: 500/4,000/20,000 A)
Voltage ±0.2% reading, 10% fs…fs
Current ±0.4% reading, 5% fs…fs
Power ±0.5% reading +0.1% fs (PF=1)
Frequency ±0.1% reading ±1 digit at 45…65 Hz
   
Accuracy classes  
Active energy Class 1 acc. to IEC/EN 62053-21
Reactive energy Class 2 acc. to IEC/EN 62053-23
   
Display Backlit LCD display, 78 × 61 mm
   
Protocols Modbus TCP (HTTP Web server), Modbus RTU/ASCII
Baud rate 300…57,600 bps, 10/100 Mbps (TCP)
Pulse output 27 V DC, 27 mA
   
Measuring terminals Current/voltage 2.5 mm²
  Inputs/outputs, RS-Por t 1.5 mm²
Dimensions (W × H × D) in mm 96 × 96 × 40
Weight 450 g
Operating temperature 25…+55°C
Storage temperature –25°C…+75°C
Humidity Max. 80%
Degree of Protection IP 54 (only when installed in a housing) IP 20 (terminals)

 

Other views

Variants



  • UBN309 6A B RS   Item number: 003355 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Four-quadrant measurement energy
    Limit value monitoring
    Output: 2x digital
    RAM: 1 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A transformer measurement, 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC
    Communication: RS485 (Modbus RTU) + 2DO


  • UBN309 6A E LAN   Item number: 003356 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    output: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A Wandlermessung, 2-,3- oder 4-Leiternetze, 3×10/17…3×285/495VAC
    Communication: RJ45 – LAN (Mobbus TCP) + 2 DO


  • UBN309 6A E RS   Item number: 003354 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 1/5A transformer measurement, 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC
    Communication: RS485 (Modbus RTU) + 2DO


  • UBN309 RGW30 E LAN 3M   Item number: 003365 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    output: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 30cm
    Communication: Modbus TCP


  • UBN309 RGW45 E LAN 3M   Item number: 003367 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 45cm
    Communication: Modbus TCP


  • UBN309 RGW70 E LAN 3M   Item number: 003368 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 70cm
    Communication: Modbus TCP


  • UBN309 RGW90 E LAN 3M   Item number: 004123 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    Outputs: 2x digital
    RAM: 8 MB
    Design: front door 96x96mm
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, Rogoski transformer measurement, coil length 90cm
    Communication: Modbus TCP

*Different cable lengths for Rogowski coils on request.


UBN 40/UBN 40 Rogowski Kit

The UBN 40 is a modern device for measurement and storage as well as consumption analysis of energy values. Due to the different variants such as direct or transformer measurement and the option to connect using flexible Rogowski coils, the UBN 40 offers a wide range of measurement possibilities. The UBN 40 kit includes suitable Rogowski coils.

All parameters can be set and programmed directly on the power analyzer via three keys. With a width of four modules, the device can be installed in the control cabinet in a space-saving manner. Due to different data interfaces (Modbus RTU/TCP) and an integrated Web server, it can be optimally integrated into existing systems or read remotely via Web interface. The device is suitable for the following areas of application: energy audits, energy and load management, and network and machine monitoring.

Features

  • 4 module width, top-hat rail mounting
  • 8 MB memory for MIN/MAX/average values
  • Bi-directional four-quadrant measurement
  • Measurement in 1-, 3-, or 4-wire networks
  • Optional: Modbus RTU or TCP
  • Integrated HTTP Web server (TCP variant)

Technical data

Power supply  
Voltage 85…265 V AC (external)
Frequency 50/60 Hz
Power consumption 1.5 V AC max.
Voltage inputs 3× 10/17 … 3× 285/495 V AC
Load Max. 3 V AC pro phase
Current inputs  
Measuring current 1(5) A transformer measurement
  80 A direct measurement
  Flexible Rogowski measurement (MFC150)
Measurement accuracy  
Voltage ±0.2% display, ±10% fs
Current ±0.4% display, ±0.1% fs
Power ±0.5% display, ±0.1% fs
Frequency ±0,1% display ±1 digit at 45…65 Hz
Accuracy classes Active energy: Class 1 acc. to IEC/EN 62053-21
  Reactive energy: Class 2 acc. to IEC/EN 62053-23
Communication interface  
Type RS485 (Modbus RTU, ASCII) + Modbus TCP
Baud rate 300…57,600 baud
Operating temperature –25…+55°C
Storage temperature –25…+75°C
Humidity Max. 80% noncondensing
Case
Material Plastic case
Protection Unit IP 20 (terminals) + IP 51 (only when mounted in a case)
Terminals 1.5…6 mm² (for transformer measurement)
  1.5…35 mm² (for direct measurement)
Dimensions (W × H × D) in mm 72 × 90 × 65

 

Variants



  • UBN40 6A LAN   Item number: 003307 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection networks: 1/5A, 2-,3- or 4-wire networks, 3×10/17 …3×285/495 VAC
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 6A RS   Item number: 003306 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection Networks: 1/5A, 2-,3- or 4-wire networks, 3×10/17 …3×285/495 VAC
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 80A LAN   Item number: 003302 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection Networks: 2x 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, 80A
    Communication: RJ45 – LAN (Mobbus TCP)


  • UBN40 80A RS   Item number: 003301 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, 80A
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 RGW KIT30 LAN 3M   Item number: 003315 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 30cm
    Communication: RJ45 – LAN (Mobbus TCP)


  • UBN40 RGW KIT30 RS 3M   Item number: 003303 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 30cm
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 RGW KIT45 LAN 3M   Item number: 003317 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 45cm
    Communication: RJ45 – LAN (Mobbus TCP)


  • UBN40 RGW KIT45 RS 3M   Item number: 003316 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection networks: 2-,3- oder 4-Leiternetze, 3×10/17…3×285/495VAC, Kabellänge 3m, Spulenlänge 45cm
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 RGW KIT70 LAN 3M   Item number: 003304 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 70cm
    Communication: RJ45 – LAN (Mobbus TCP)


  • UBN40 RGW KIT70 RS 3M   Item number: 003318 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 70cm
    Communication: RS485 (Modbus RTU) + 1DO


  • UBN40 RGW KIT90 LAN 3M   Item number: 004124 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    integrated web server
    RAM: 8 MB
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 90cm
    Communication: RJ45 – LAN (Mobbus TCP)


  • UBN40 RGW KIT90 RS 3M   Item number: 004125 Mains monitoring module
    Multi-measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Harmonics (U, I) 15. harmonics
    Four-quadrant measurement Energy
    Limit monitoring
    Output: 1x digital
    RAM: 8 MB
    Connection Networks: 2-,3- or 4-wire networks, 3×10/17…3×285/495VAC, cable length 3m, coil length 90cm
    Communication: RS485 (Modbus RTU) + 1DO
  • Different cable lengths for Rogowski coils on request.


Advanced Monitoring (AM) with Network Analyzers

UBN AM power analyzers are compact devices for measuring and monitoring power networks. They are characterized by precision and intuitive operation. The UBN AM meets all the requirements of advanced network monitoring and can be individually adapted to almost any measurement task thanks to optional expansion components. The process environment can be connected with optional communication interfaces, via digital I/Os, analog outputs, or relays.

The devices are used in industrial plants, building automation, or power distribution. In low-voltage networks, nominal voltages up to 690 V CAT III can be connected directly; phase currents are detected via current transformers. The universal measuring system allows the use of the UBN-AM in all common network types.
Via the TFT display of the UBN power analyzer, the device can be operated and parameterized locally or, thanks to the integrated Web server, on mobile or stationary end devices. A comprehensive security concept protects the UBN from data manipulation or unauthorized network access. Data transmission is HTTPS encrypted, and measured value visualization in Efficio (release 5.0 or later) can be performed using website widgets.

ubn-am1000

UBN AM1000

UBN AM1000 power analyzers are designed for panel mounting with a standard 96 × 96 mm cutout. They have three measurement inputs each for connection of current and voltage transformers, an Ethernet interface (Modbus TCP, HTTPS, NTP), two digital outputs, and an expansion option. The measuring accuracy for currents/voltages is 0.2%, for power 0.5%, and for energy values 1%.

Technical data

Basic features

 

  • For 96 × 96 mm panel mounting
  • 3 current and 3 voltage measurement channels with 0.2% accuracy, direct measurement, or via current and voltage transformers
  • Measurement category 600 V, CAT III (voltage), 300 V, CAT III (current)
  • Standard I/Os: 1 digital output, 1 digital input
  • Extensions: 1 hardware option
  • Internal data logger 4 GB (option: UBN AM1000 EW.LOG)
  • Monitoring and alerting via limit values and monitoring functions
Network status

 

  • Provision of all voltages, currents, powers, power factors every 10/12 periods
  • Extended reactive power analysis
  • Variance of network variables with time reference
Energy flow analysis

 

  • Load curve storage with variation bandwidth (min./max.) per interval
  • Active/reactive energy Class 1 (HT/NT, purchase/delivery), programmable resolution
  • Additional averages and counters with selectable base variable
Power quality

 

  • Harmonic analysis acc. to IEC 61000-4-7
  • Evaluation of voltage and current imbalances
  • Vector and rotation direction display for connection control
  • Waveform display
Hardware option

 

  • Analog outputs ±20 mA (2/4)
  • Relay outputs (2)
  • Digital inputs (4) active/passive
  • GPS time synchronization
  • Residual current detection (differential or ground current)
  • Temperature monitoring (Pt100, PTC)
  • IEC 61850
  • Profinet I/O
Communication

 

  • Ethernet (Modbus/TCP, http/https, NTP, SFTP, SYSLOG), IEC 61850, Profinet I/O, Modbus/RTU
  • Automated data export to SFTP server (push operation)
Security features
  • Flexible role-based access control
  • Encrypted communication via HTTPS
  • Audit log registers all security-related operations, SYSLOG support for transfer to central monitoring server
  • Client whitelist: IP address list for restricting access-authorized computers
  • Digital firmware signature: manipulated firmware files cannot be imported onto the device

Other views

UBN AM1000 Multifunktionsmessgerät von Berg - Ansicht von Rechts UBN AM1000 Multifunktionsmessgerät Frontansicht Produktbild-ubn-am1000-seitenansicht

Variants



  • UBN AM1000 power analyzer   Item number: 004967 Basic version
    96×96 mm panel mount unit
    Interface: 1x RJ45 Ethernet 100baseTx (web server)
    Standard I/O: 1x passive digital input, 1x passive digital output
    Auxiliary voltage: 230 VAC, 50/60 Hz

* Optional configuration: Extension of internal 4 GB data memory for multimeter (art. no.: 004969)

Interfaces and accessories



  • UBN AM1000 4GB Data Storage   Item number: 004969 Data memory 4 GB
    for archiving periodic measurement data and
    events in multifunction device AM1000


  • UBN PQ_AM Analog Output Card   Item number: 004954 Analog output card
    dual, bipolar +-20 mA for signal output
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Supply 24V DC   Item number: 004961 RS485 interface card with Modbus RTU protocol integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Voltage 24V DC   Item number: 004970 Auxiliary Supply 24V DC
    Replacement for the 230VAC standard supply of a
    Netzqualitätsanalysators PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Active   Item number: 004960 Digital input card active
    quadruple, active for signal/pulse acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Passive   Item number: 004955 Digital input card passive
    quadruple, passive for signal acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM IEC61850   Item number: 004958 IEC 61850 interface card (TCP/IP)
    transmission protocol for station automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Profinet   Item number: 004959 Profinet interface card (TCP/IP)
    Industrial Ethernet PNO compliant automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Residual Current Detection   Item number: 004956 Residual current detection
    two-channel module integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Switching Output Card   Item number: 004953 Switching output card
    Relay dual for alarm output integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000

UBN AM2000

UBN AM2000 power analyzers are designed for panel mounting with the standard 144 × 144 mm cutout. They have three measurement inputs each for connection of current and voltage transformers, an Ethernet interface (Modbus TCP, HTTPS, NTP), one digital input, two digital outputs, and four expansion options. The measurement accuracy for currents/voltages is 0.2%, for power 0.5%, and for energy values 1%.

Technical data

Basic features
  • For 144 × 144 mm panel mounting
  • 3 current and 3 voltage measurement channels with 0.2% accuracy, direct measurement, or via current and voltage transformers
  • Measurement category 600 V, CAT III (voltage), 300 V, CAT III (current)
  • Standard I/Os: 2 digital outputs, 1 digital input
  • Extensions: 1 hardware option
  • Data logger with 16 GB (option: UBN AM2000 EW.LOG)
  • Monitoring and alerting via limit values and monitoring functions
Network status
  • Provision of all voltages, currents, powers, power factors every 10/12 periods
  • Extended reactive power analysis
  • Variance of network variables with time reference
Energy flow analysis
  • Load curve storage with variation bandwidth (min/max) per interval (min. resolution 10 sec.)
  • Active/reactive energy class 1 (HT/NT, supply/discharge), programmable resolution
  • Further averages and counters with selectable base value
Power quality
  • Harmonic analysis acc. to IEC 61000-4-7
  • Evaluation of voltage and current imbalances
  • Vector and rotation direction display for connection control
  • Waveform display
Hardware option Up to 4 expansion modules selectable:

  • Analog outputs ±20 mA (2/4)
  • Relay outputs (2)
  • Digital inputs (4) active/passive
  • GPS time synchronization
  • UPS (5× 3 min.)
  • Fault current detection (differential or ground wire current)
  • Temperature monitoring (Pt100, PTC)
  • IEC 61850
  • Profinet I/O
Communication

 

  • Ethernet (Modbus/TCP, http/https, NTP, SFTP, SYSLOG)
  • IEC 61850
  • Profinet I/O
  • RS485 (Modbus/RTU)
  • Automated data export to SFTP server (push operation)
Security features
  • Flexible role-based access control
  • Encrypted communication via HTTPS
  • Audit log registers all security-relevant operations, support of SYSLOG for transfer to central monitoring server
  • Client whitelist: IP address list for restricting access-authorized computers
  • Digital firmware signature: manipulated firmware files cannot be imported onto the device

Other views

Variant



  • UBN AM2000 power analyzer   Item number: 004966 Basic version
    144×144 mm panel mount unit
    Interface: 1x RJ45 Ethernet 100baseTx (web server)
    Serial: 1x RS485 (Modbus RTU)
    Standard I/O: 1x passive digital input, 2x passive digital output
    Auxiliary voltage: 230 VAC, 50/60 Hz

Interfaces and accessories



  • UBN AM1000 4GB Data Storage   Item number: 004969 Data memory 4 GB
    for archiving periodic measurement data and
    events in multifunction device AM1000


  • UBN PQ_AM Analog Output Card   Item number: 004954 Analog output card
    dual, bipolar +-20 mA for signal output
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Supply 24V DC   Item number: 004961 RS485 interface card with Modbus RTU protocol integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Voltage 24V DC   Item number: 004970 Auxiliary Supply 24V DC
    Replacement for the 230VAC standard supply of a
    Netzqualitätsanalysators PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Active   Item number: 004960 Digital input card active
    quadruple, active for signal/pulse acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Passive   Item number: 004955 Digital input card passive
    quadruple, passive for signal acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM IEC61850   Item number: 004958 IEC 61850 interface card (TCP/IP)
    transmission protocol for station automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Profinet   Item number: 004959 Profinet interface card (TCP/IP)
    Industrial Ethernet PNO compliant automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Residual Current Detection   Item number: 004956 Residual current detection
    two-channel module integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Switching Output Card   Item number: 004953 Switching output card
    Relay dual for alarm output integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


ubn-am3000

UBN AM3000

UBN AM3000 power analyzers are designed for panel mounting with a 144 × 144 mm standard cutout. They have four measurement inputs each for connecting current and voltage transformers as well as measurement inputs for residual current detection or residual current measurement. The basic model is equipped with an Ethernet interface (Modbus TCP, HTTPS, NTP), one digital input, and two digital outputs. Up to four expansion options can be added. The measurement accuracy of the UBN AM3000 is 0.2% for currents/voltages, 0.5% for power, and 0.5% for energy values.

Technical data

Basic features
  • For 144 × 144 mm panel mounting
  • 4 current and voltage measurement channels with 0.1% accuracy, direct measurement up to 690 V LL, or via current and voltage transformers
  • Measurement category 600 V, CAT III (voltage), 300 V, CAT III (current)
  • Standard I/Os: 2 digital outputs, 1 digital input
  • Data logger 16 GB microSD card (option: UBN AM3000 EW.LOG)
  • Monitoring and alerting via limit values and monitoring functions
Network status
  • Provision of all voltages, currents, powers, power factors every 10/12 periods
  • Extended reactive power analysis
  • Variance of network variables with time reference
Energy flow analysis
  • Load curve storage with variation bandwidth (min./max.) per interval
  • Active/reactive energy Class 1 (HT/NT, purchase/delivery), programmable resolution
  • Additional averages and counters with selectable base variable
Power quality
  • Harmonic analysis acc. to IEC 61000-4-7
  • Evaluation of voltage and current imbalances
  • Vector and rotation direction display for connection control
  • Waveform display
  • Optional disturbance recorder for PQ events (voltage dip, voltage rise, voltage dip) acc. to IEC 61000-4-30 Ed.3 with RMS1/2 and waveform storage
Hardware option

 

Up to 4 expansion modules selectable:

  • Analog outputs ±20 mA (2/4)
  • Relay outputs (2)
  • Digital inputs (4) active/passive
  • GPS time synchronization
  • UPS (5× 3 min.)
  • Residual current detection (differential or ground current)
  • Temperature monitoring (Pt100, PTC)
  • IEC 61850
  • Profinet I/O
Communication

 

  • Ethernet (Modbus/TCP, http/https, NTP, SFTP, SYSLOG)
  • IEC 61850
  • Profinet I/O
  • RS485 (Modbus/RTU)
  • Automated data export to SFTP server (push operation)
Security features
  • Flexible role-based access control
  • Encrypted communication via HTTPS
  • Audit log registers all security-relevant operations, support of SYSLOG for transfer to central monitoring server
  • Client whitelist: IP address list for restricting access-authorized computers
  • Digital firmware signature: manipulated firmware files cannot be imported onto the device

Other views

UBN AM3000 Multifunktionsmessgerät von Berg - Frontansicht UBN AM3000 Multimessgerät von Berg - Ansicht von Links

Variant



  • UBN AM3000 power analyzer   Item number: 004965 Basic version
    144x144mm panel mount unit
    Interface: 1x RJ45 Ethernet 100baseTx, 2 ports
    Protocols: Modbus TCP, http, NTP
    Standard I/O: 1x passive digital input, 2x passive digital outpu

Interfaces and accessories



  • UBN AM3000 16GB Data Storage   Item number: 004985 Data memory 16 GB
    for archiving periodic measurement data and
    events in multifunction device AM3000


  • UBN PQ_AM Analog Output Card   Item number: 004954 Analog output card
    dual, bipolar +-20 mA for signal output
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Supply 24V DC   Item number: 004961 RS485 interface card with Modbus RTU protocol integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Voltage 24V DC   Item number: 004970 Auxiliary Supply 24V DC
    Replacement for the 230VAC standard supply of a
    Netzqualitätsanalysators PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Active   Item number: 004960 Digital input card active
    quadruple, active for signal/pulse acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Passive   Item number: 004955 Digital input card passive
    quadruple, passive for signal acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM IEC61850   Item number: 004958 IEC 61850 interface card (TCP/IP)
    transmission protocol for station automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Profinet   Item number: 004959 Profinet interface card (TCP/IP)
    Industrial Ethernet PNO compliant automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Residual Current Detection   Item number: 004956 Residual current detection
    two-channel module integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Switching Output Card   Item number: 004953 Switching output card
    Relay dual for alarm output integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM UPS Battery   Item number: 004952 UPS Battery
    uninterruptible power supply 1.150 mAh battery
    power reserve 5 x 3min integrated in power quality analyzer PQ3000/PQ5000
    or multifunctional device AM3000

Power Quality (PQ) with Power Quality Analyzers

The devices of the UBN PQ series are compact devices for qualitative measurement and monitoring of power networks. They can be directly connected to nominal voltages up to 690 V CAT III, and phase currents can be measured via current transformers with harmonic capability, for example, Berg XCTB. The universal measuring system allows the use of the UBN PQ1000, PQ3000, and PQ5000 devices in all common network types.


The products of the PQ series are metrologically certified devices of class A or S according to IEC 61000-4-30 Ed. 3. They provide reliable information for negotiations with energy suppliers or internal power quality control. Continuous monitoring can be used to analyze faults and archive them in the device’s long-term memory. The report generator integrated on the Web server enables intuitive generation of a power quality report according to EN 50160, EN 61000-2/4/12, or internal company limits without additional external software.
The PQ devices are connected to the process environment via communication interfaces, digital I/Os, analog outputs, or relays. A comprehensive security concept protects the UBN PQ devices against data manipulation or unauthorized network access. The data transmission is HTTPS encrypted, and the measured value visualization in the energy management software Efficio (release 5.0 or later) is possible using website widgets.

ubn-am1000

UBN PQ1000

UBN PQ1000 power quality analyzers provide continuous power quality assessment according to IEC 61000-4-30 Ed.3 in class S and are designed for panel mounting with the standard 96 x 96 mm cutout. They each have three measurement inputs for connecting harmonic-capable current and voltage transformers, an Ethernet interface (Modbus TCP, HTTPS, NTP), two digital outputs, and an expansion option. The measurement accuracy for phase currents/voltages is 0.2%, for power 0.5%, harmonics 0.5%, THD/THH 0.5%, and for energy values 0.5% (kWh/kVarh).

Technical data

Basic features
  • For 96 × 96 mm panel mounting
  • 3 current and 3 voltage measurement channels with 0.2% accuracy, direct measurement, or via current and voltage transformers
  • Measurement category 600 V, CAT III (voltage), 300 V, CAT III (current)
  • Standard I/Os: 1 digital output, 1 digital input/output
  • Data logger with 16 GB memory
  • Sampling rate: 18 kHz
  • Monitoring and alerting via limit values and monitoring functions
Network status
  • Provision of all voltages, currents, powers, power factors every 10/12 periods
  • Extended reactive power analysis
  • Variance of network variables with time reference
Energy flow analysis
  • Load curve storage with variation bandwidth (min./max.) per interval
  • Active/reactive energy Class 0.5S (HT/NT, purchase/delivery), programmable resolution
  • Further averages and counters with selectable base value
Power quality
  • Evaluation acc. to EN 50160, IEC 61000-2/4/12, IEEE 519, or self-defined limits
  • Conformity reports can be generated directly via device website (PQEasy report).
  • Independent certification acc. to IEC 62586-2 by the Swiss Federal Institute of Metrology METAS
  • Support of the standardized, manufacturer-independent PQDIF format acc. to IEEE 1159.3
  • Adjustable event recording duration: Up to 6 seconds for waveform and 3 minutes for RMS values
  • Event display via the website with time zoom and value reading
  • Evaluation of voltage and current imbalances
  • Vector and rotation direction display for connection control
  • Waveform display
Hardware option

 

One expansion module selectable:

  • Analog outputs ±20 mA (2/4),
  • Relay outputs (2),
  • Digital inputs (4) active/passive,
  • GPS time synchronization,
  • Fault current detection (differential or ground wire current),
  • Temperature monitoring (Pt100, PTC),
  • IEC 61850
  • Profinet I/O
Communication

 

  • Ethernet (Modbus/TCP, http/https, NTP, SFTP, SYSLOG), IEC 61850, Profinet I/O, Modbus/RTU
  • Automated data export to SFTP server
Security features
  • Flexible role-based access control
  • Encrypted communication via HTTPS
  • Audit log registers all security related events, support of SYSLOG for transfer to central monitoring server
  • Client whitelist: IP address list for restricting access-authorized computers
  • Digital firmware signature: manipulated firmware files cannot be imported onto the device

Documents download

Variant



  • UBN PQ1000 Power Quality Analyzer   Item number: 004996 Basic version
    96 x 96 mm panel mount unit
    Power quality analysis class A IEC 61000-4-30 Ed. 3
    Accuracy class energy: 0.2S
    Voltage measurement: 4 channels, 480V/ 832V
    Current measurement: 4 current transformers, 1 … 5A / 7.5A
    RTC, data memory: 16 GB

Interfaces and accessories



  • UBN PQ_AM Analog Output Card   Item number: 004954 Analog output card
    dual, bipolar +-20 mA for signal output
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Supply 24V DC   Item number: 004961 RS485 interface card with Modbus RTU protocol integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Voltage 24V DC   Item number: 004970 Auxiliary Supply 24V DC
    Replacement for the 230VAC standard supply of a
    Netzqualitätsanalysators PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Active   Item number: 004960 Digital input card active
    quadruple, active for signal/pulse acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Passive   Item number: 004955 Digital input card passive
    quadruple, passive for signal acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM IEC61850   Item number: 004958 IEC 61850 interface card (TCP/IP)
    transmission protocol for station automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Profinet   Item number: 004959 Profinet interface card (TCP/IP)
    Industrial Ethernet PNO compliant automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Residual Current Detection   Item number: 004956 Residual current detection
    two-channel module integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Switching Output Card   Item number: 004953 Switching output card
    Relay dual for alarm output integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000

UBN PQ3000

UBN PQ3000 power quality analyzers provide continuous power quality assessment according to IEC 61000-4-30 Ed.3 in class A and are designed for panel mounting with the standard 144 × 144 mm cutout. They each have four measurement inputs for connecting current and voltage transformers, an Ethernet interface (Modbus TCP, HTTPS, NTP), two digital outputs, and three expansion options. The measurement accuracy for phase currents/voltages is 0.1%, for power 0.2%, harmonics 0.5%, THD/THH 0.5 and for energy values 0.2% (kWh) and 0.5% (kVarh).

Technical data

Basic features
  • For 144 × 144 mm panel mounting
  • 4 current and voltage measurement channels with 0.1% accuracy, direct measurement, or via current and voltage transformers
  • Measurement category 600 V, CAT III (voltage), 300 V, CAT III (current)
  • Standard I/Os: 2 digital outputs, 1 digital input/output
  • Data logger with 16 GB memory
  • Sampling rate: 18 kHz
  • Monitoring and alerting via limit values and monitoring functions
Network status
  • Provision of all voltages, currents, powers, power factors every 10/12 periods
  • Extended reactive power analysis
  • Variance of network variables with time reference
Energy flow analysis
  • Load curve storage with variation bandwidth (min./max.) per interval
  • Active/reactive energy class 0.2S/0.5S (HT/NT, purchase/delivery), programmable resolution
  • Further averages and counters with selectable base value
Power quality
  • Evaluation acc. to EN 50160, IEC 61000-2/4/12, IEEE 519, or self-defined limits
  • Conformity reports can be generated directly using the device website (PQEasy report)
  • Independent certification according to IEC 62586-2 by Swiss Federal Institute of Metrology METAS
  • Support of the standardized, manufacturer-independent PQDIF format acc. to IEEE 1159.3
  • Adjustable event recording duration: Up to 6 seconds for waveform and 3 minutes for RMS values
  • Event display via the website with time zoom and value reading
  • Evaluation of voltage and current imbalances
  • Vector and rotation direction display for connection control
  • Waveform display
Hardware option

 

Up to three expansion modules selectable:

  • Analog outputs ±20 mA (2/4),
  • Relay outputs (2),
  • Digital inputs (4) active/passive,
  • GPS time synchronization,
  • Fault current detection (differential or ground wire current),
  • Temperature monitoring (Pt100, PTC),
  • IEC 61850
  • Profinet I/O
Communication

 

  • Ethernet (Modbus/TCP, http/https, NTP, SFTP, SYSLOG), IEC 61850, Profinet I/O, Modbus/RTU
  • Automated data export (CSV and PQDIF format) to SFTP server
Security features
  • Flexible role-based access control
  • Encrypted communication via HTTPS
  • Audit log registers all security-related events, SYSLOG support for transfer to central monitoring server
  • Client whitelist: IP address list for restricting access-authorized computers
  • Digital firmware signature: manipulated firmware files cannot be imported onto the device

Documents download

Other views

UBN PQ3000 Multifunktionsmessgerät von Berg - Ansicht von Rechts, im Display Abbildung eines Vektordiagramm  UBN PQ3000 Multifunktionsmessgerät Frontansicht   UBN PQ3000 Multifunktionsmessgerät von Berg - Ansicht von Links, im Display Abbildung der Abtastwerte

Variant



  • UBN PQ3000 Power Quality Analyzer   Item number: 004962 Basic version
    144 x 144 mm panel mount unit
    Power quality analysis class A IEC 61000-4-30 Ed. 3
    Accuracy class energy: 0.2S
    Voltage measurement: 4 channels, 480V/ 832V
    Current measurement: 4 current transformers, 1 … 5A / 7.5A
    RTC, data memory: 16 GB

Interfaces and accessories



  • UBN PQ_AM Analog Output Card   Item number: 004954 Analog output card
    dual, bipolar +-20 mA for signal output
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Supply 24V DC   Item number: 004961 RS485 interface card with Modbus RTU protocol integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Voltage 24V DC   Item number: 004970 Auxiliary Supply 24V DC
    Replacement for the 230VAC standard supply of a
    Netzqualitätsanalysators PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Active   Item number: 004960 Digital input card active
    quadruple, active for signal/pulse acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Passive   Item number: 004955 Digital input card passive
    quadruple, passive for signal acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM IEC61850   Item number: 004958 IEC 61850 interface card (TCP/IP)
    transmission protocol for station automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Profinet   Item number: 004959 Profinet interface card (TCP/IP)
    Industrial Ethernet PNO compliant automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Residual Current Detection   Item number: 004956 Residual current detection
    two-channel module integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Switching Output Card   Item number: 004953 Switching output card
    Relay dual for alarm output integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM UPS Battery   Item number: 004952 UPS Battery
    uninterruptible power supply 1.150 mAh battery
    power reserve 5 x 3min integrated in power quality analyzer PQ3000/PQ5000
    or multifunctional device AM3000
produktfoto-ubn-pq3000


produktfoto-ubn-pq5000

UBN PQ5000

UBN PQ5000 power quality analyzers provide continuous power quality assessment according to IEC 61000-4-30 Ed.3 in class A and are designed for a DIN rail mounting. They each have four measurement inputs for connecting current and voltage transformers, an Ethernet interface (Modbus TCP, HTTPS, NTP), two digital outputs, and two expansion options. The measurement accuracy for phase currents/voltages is 0.1%, for power 0.2%, harmonics 0.5%, THD/THH 0.5% and for energy values 0.2% (kWh) and 0.5% (kVarh).

Technical data

Basic features
  • For DIN rail mounting (W × H × D: 160 × 110 × 70 mm)
  • 4 current and voltage measurement channels with 0.1% accuracy, direct measurement, or via current and voltage transformers
  • Measurement category 600 V, CAT III (voltage), 300 V, CAT III (current)
  • Standard I/Os: 2 digital outputs, 1 digital input/output
  • Data logger with 16 GB memory
  • Sampling rate: 18 kHz
  • Monitoring and alerting via limit values and monitoring functions
Network status
  • Provision of all voltages, currents, powers, power factors every 10/12 periods
  • Extended reactive power analysis
  • Variance of network variables with time reference
Energy flow analysis
  • Load curve storage with variation bandwidth (min./max.) per interval
  • Active/reactive energy class 0.2S/0.5S (HT/NT, purchase/delivery), programmable resolution
  • Further averages and counters with selectable base value
Power quality
  • Evaluation acc. to EN 50160, IEC 61000-2/4/12, IEEE 519 or self-defined limit
  • Conformity reports can be generated directly via device website (PQEasy report)
  • Independent certification acc. to IEC 62586-2 by the Swiss Federal Institute of Metrology METAS
  • Support of the standardized, manufacturer-independent PQDIF format acc. to IEEE 1159.3
  • Adjustable event recording duration: up to 6 seconds for waveform and 3 minutes for RMS values
  • Event display via the website with time zoom and value reading
  • Evaluation of voltage and current imbalances
  • Vector and rotation direction display for connection control
  • Waveform display
Hardware option

 

Up to two expansion modules selectable:

  • Analog outputs ±20 mA (2/4),
  • Relay outputs (2),
  • Digital inputs (4) active/passive,
  • GPS time synchronization,
  • Fault current detection (differential or ground wire current),
  • Temperature monitoring (Pt100, PTC),
  • IEC 61850
  • Profinet I/O
Communication

 

  • Ethernet (Modbus/TCP, http/https, NTP, SFTP, SYSLOG), IEC 61850, Profinet I/O, Modbus/RTU
  • Automated data export (CSV and PQDIF format) to SFTP server
Security features
  • Flexible role-based access control
  • Encrypted communication via HTTPS
  • Audit log registers all security-related events, SYSLOG support for transfer to central monitoring server
  • Client whitelist: IP address list for restricting access-authorized computers
  • Digital firmware signature: manipulated firmware files cannot be imported onto the device

Documents download

Other views

Variant



  • UBN PQ3000 Power Quality Analyzer   Item number: 004951 Basic version
    160 x 110 mm top-hat rail
    Power quality analysis class A IEC 61000-4-30 Ed. 3
    Accuracy class energy: 0.2S
    Voltage measurement: 4 channels, LN/LL 520V / 900V
    Current measurement: 4 current transformers1/5A
    Data memory: 16 GB

Interfaces and accessories



  • UBN PQ_AM Analog Output Card   Item number: 004954 Analog output card
    dual, bipolar +-20 mA for signal output
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Supply 24V DC   Item number: 004961 RS485 interface card with Modbus RTU protocol integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Auxiliary Voltage 24V DC   Item number: 004970 Auxiliary Supply 24V DC
    Replacement for the 230VAC standard supply of a
    Netzqualitätsanalysators PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Active   Item number: 004960 Digital input card active
    quadruple, active for signal/pulse acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Digital Input Card Passive   Item number: 004955 Digital input card passive
    quadruple, passive for signal acquisition
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM IEC61850   Item number: 004958 IEC 61850 interface card (TCP/IP)
    transmission protocol for station automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Profinet   Item number: 004959 Profinet interface card (TCP/IP)
    Industrial Ethernet PNO compliant automation
    integrated in power quality analyzer PQ1000/3000/5000
    or multifunctional device AM1000/AM2000/AM3000


  • UBN PQ_AM Residual Current Detection   Item number: 004956 Residual current detection
    two-channel module integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunction device AM1000/AM2000/AM3000


  • UBN PQ_AM Switching Output Card   Item number: 004953 Switching output card
    Relay dual for alarm output integrated in
    Netzqualitätsanalysator PQ1000/3000/5000
    or multifunctional unit AM1000/AM2000/AM3000


  • UBN PQ_AM UPS Battery   Item number: 004952 UPS Battery
    uninterruptible power supply 1.150 mAh battery
    power reserve 5 x 3min integrated in power quality analyzer PQ3000/PQ5000
    or multifunctional device AM3000

Fragen Sie uns!
Unser zuständiger Ansprechpartner ruft Sie gern zurück und beantwortet Ihre Fragen. Bitte wählen Sie einen Themenbereich, zu dem Sie ganz individuell beraten werden möchten.
Für die Verarbeitung Ihrer personenbezogenen Daten gilt unsere Datenschutzerklärung.
Just Ask Us
Our responsible contact person will be happy to call you back and answer your questions. Please select a subject area on which you would like to receive individual advice.
The processing of your personal data is governed by our Datenschutzerklärung.