Showing 17–32 of 40 results
-
BME462 IMPULS Item number: 003919 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Design: top-hat rail
Connection networks: 1(6) A, 3×230/400V
Calibration: MID
Communication: Impulse (2x S0)
-
BME462 M-BUS Item number: 003920 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Design: top-hat rail
Connection Networks: 1(6)A, 3×230/400V
Calibration: MID
Communication: M-Bus (protocol paramentrable)
-
BME462 MODBUS Item number: 003921 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Design: top-hat rail
Connection networks: 1(6) A, 3×230/400V
Calibration: MID
Communication: RS485 (Modbus RTU)
-
BME462 TCP/IP Item number: 003922 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
integrated web server
Design: top-hat rail
Connection Networks: 1(6)A, 3×230/400V
Calibration: MID
Communication: RJ45 – LAN (ModbusTCP, BacNet)
-
DCi461WP Item number: 003118 Two-quadrant measurement (+kWh,-kWh, Optional: +kVarh,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Tariff register: 1, Optional: multi-tariff controlled via digital inputs
Multimeter function (U, I, P, S, In)
Design: top-hat rail
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID
Communication: Impulse (2x S0)
-
DCi462WP Item number: 001814 Two-quadrant measurement (+kWh,-kWh, Optional: +kVarh,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Tariff register: 1, Optional: multi-tariff controlled via digital inputs
Multimeter function (U, I, P, S, In)
Design: top-hat rail
Connection Networks: 1(6)A, 3×230/400V
Calibration: MID
Communication: Impulse (2x S0)
-
Accuracy class B (1%) kWh; - (2%) kVarh
memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 RS485 (M-Bus* oder SML) + 2x S0
Connection Networks: 5(80)A, 1x230V
Calibration: MID PTB-A 50.7
-
DCLI251KPL Item number: 004586 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection networks: 5(80)A, 1x 230V
Calibration: MID PTB-A 50.7
-
DCLI332KPL Item number: 004575 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection Networks: 1(6)A, 3x100V
Calibration: MID PTB-A 50.7
-
DCLI351KPL Item number: 004636 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection networks: 5(80)A, 3x 230V
Calibration: MID PTB-A 50.7
-
DCLI352KPL Item number: 004634 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection Networks: 1(6)A, 3x230V
Calibration: MID PTB-A 50.7
-
DCLI361KPL Item number: 004637 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection Networks: 5(80)A, 3x400V
-
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection Networks: 1(6)A, 3x400V
Calibration: MID PTB-A 50.7
-
DCLI362KPL Item number: 004635 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection Networks: 1(6)A, 3x400V
Calibration: MID PTB-A 50.7
-
DCLI432KPL Item number: 004632 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimetering function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* or SML) + 2x S0
Connection Networks: 1(6)A, 3×58/100V
Calibration: MID PTB-A 50.7
-
DCLI461KPL Item number: 004473 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
memory (PTB compliant meter reading)
with RTC clock (synchronization via data interface)
Multimeter function (U, I, P, S, In)
Design: top-hat rail
Communication: RJ12 – RS485 (M-Bus* oder SML) + 2x S0
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID PTB-A 50.7