  • B23 311-IMPULS   Item number: 002700 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B (1%) kWh; - (2%) kVarh
    Tariff registers: 4 (controlled by digital inputs)
    Multimeter function (U, I, P, Q, S, PF, f, In)
    Limit value monitoring with 2 alarm outputs
    Design: top-hat rail
    Connection Networks: 3×230/400V; 3x400V; 5(65)A
    Calibration: MID
    Communication: Impulse (2x S0)


  • B23 312-MODBUS   Item number: 002702 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class C (0,5%) kWh; - (2%) kVarh
    Tariff registers: 4 (controlled by digital inputs)
    Multimeter function (U, I, P, Q, S, PF, f, In)
    Limit value monitoring with 2 alarm outputs
    Design: top-hat rail
    Connection networks: 3×230/400V, 3x400V, 5(65)A
    Calibration: MID
    Communication: RS485 (Modbus RTU) + 2x S0


  • B23 313-M-BUS   Item number: 002703 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B (1%) kWh; - (2%) kVarh
    Tariff registers: 4 (controlled by digital inputs)
    Multimeter function (U, I, P, Q, S, PF, f, In)
    Limit value monitoring with 2 alarm outputs
    Design: top-hat rail
    Connection networks: 3×230/400V, 3x400V, 5(65)A
    Calibration: MID
    Communication: M-Bus (protocol parameterizable) + 2x S0
  • B24 351-IMPULS   Item number: Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class C (0,5%) kWh; - (2%) kVarh
    Tariff registers: 4 (controlled by digital inputs)
    Multimeter function (U, I, P, Q, S, PF, f, In)
    Limit value monitoring with 2 alarm outputs
    Design: top-hat rail
    Connection networks: 1(6) A, 3×230/400V; 3x400V
    Calibration: MID
    Communication: Impulse (2x S0)


  • B24 351-IMPULS   Item number: 002704 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class C (0,5%) kWh; - (2%) kVarh
    Tariff registers: 4 (controlled by digital inputs)
    Multimeter function (U, I, P, Q, S, PF, f, In)
    Limit value monitoring with 2 alarm outputs
    Design: top-hat rail
    Connection networks: 1(6) A, 3×230/400V, 3x400V
    Calibration: MID
    Communication: Impulse (2x S0)


  • B24 352-MODBUS   Item number: 002705 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class C (0,5%) kWh; - (2%) kVarh
    Tariff registers: 4 (controlled by digital inputs)
    Multimeter function (U, I, P, Q, S, PF, f, In)
    Limit value monitoring with 2 alarm outputs
    Design: top-hat rail
    Connection networks: 1(6) A, 3×230/400V, 3x400V
    Calibration: MID
    Communication: RS485 (Modbus RTU) + 2x S0


  • B24 353-M-BUS   Item number: 002706 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class C (0,5%) kWh; - (2%) kVarh
    Tariff registers: 4 (controlled by digital inputs)
    Multimeter function (U, I, P, Q, S, PF, f, In)
    Limit value monitoring with 2 alarm outputs
    Design: top-hat rail
    Connection networks: 1(6) A, 3×230/400V, 3x400V
    Calibration: MID
    Communication: M-Bus (protocol parameterizable) + 2x S0
  • BME461 CLP   Item number: Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multi measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Integrated web server
    Design: top-hat rail
    Connection Networks: 3×230/400V
    Calibration: MID PTB-A 50.7
    Communication: Modbus TCP


  • BME461 CLP   Item number: 004872 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multi measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Integrated web server
    Design: top-hat rail
    Connection networks: 3x 230/400V
    Calibration: MID PTB-A 50.7
    Communication: Modbus TCP


  • BME461 IMPULS   Item number: 003915 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Design: top-hat rail
    Connection Networks: 5(80)A, 3×230/400V
    Calibration: MID
    Communication: Impulse (2x S0)
  • BME461 M-BUS   Item number: Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Design: top-hat rail
    Connection Networks: 5(80)A, 3×230/400V
    Calibration: MID
    Communication: M-Bus (protocol paramentrable)


  • BME461 M-BUS   Item number: 003916 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Design: top-hat rail
    Connection Networks: 5(80)A, 3×230/400V
    Calibration: MID
    Communication: M-Bus (protocol paramentrable)


  • BME461 MODBUS   Item number: 003917 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Design: top-hat rail
    Connection Networks: 5(80)A, 3×230/400V
    Calibration: MID
    Communication: RS485 (Modbus RTU)
  • BME461 TCP/IP   Item number: Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    integrated web server
    Design: top-hat rail
    Connection Networks: 5(80)A, 3×230/400V
    Calibration: MID
    Communication: RJ45 – LAN (ModbusTCP, BacNet)


  • BME461 TCP/IP   Item number: 003918 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    integrated web server
    Design: top-hat rail
    Connection Networks: 5(80)A, 3×230/400V
    Calibration: MID
    Communication: RJ45 – LAN (ModbusTCP, BacNet)


  • BME462 CLP   Item number: 004873 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
    Accuracy class B(1%) kWh; - (2%) kVarh
    Tariff registers: 8 (4 digital and 4 controlled by software)
    Multi measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
    Integrated web server
    Design: top-hat rail
    Connection Networks: 3×230/400V
    Calibration: MID PTB-A 50.7
    Communication: Mobus TCP

Fragen Sie uns!
Unser zuständiger Ansprechpartner ruft Sie gern zurück und beantwortet Ihre Fragen. Bitte wählen Sie einen Themenbereich, zu dem Sie ganz individuell beraten werden möchten.
Für die Verarbeitung Ihrer personenbezogenen Daten gilt unsere Datenschutzerklärung.
Just Ask Us
Our responsible contact person will be happy to call you back and answer your questions. Please select a subject area on which you would like to receive individual advice.
The processing of your personal data is governed by our Datenschutzerklärung.