B23 311-IMPULS Item number: 002700 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Tariff registers: 4 (controlled by digital inputs)
Multimeter function (U, I, P, Q, S, PF, f, In)
Limit value monitoring with 2 alarm outputs
Design: top-hat rail
Connection Networks: 3×230/400V; 3x400V; 5(65)A
Calibration: MID
Communication: Impulse (2x S0)
-
B23 312-MODBUS Item number: 002702 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class C (0,5%) kWh; - (2%) kVarh
Tariff registers: 4 (controlled by digital inputs)
Multimeter function (U, I, P, Q, S, PF, f, In)
Limit value monitoring with 2 alarm outputs
Design: top-hat rail
Connection networks: 3×230/400V, 3x400V, 5(65)A
Calibration: MID
Communication: RS485 (Modbus RTU) + 2x S0
-
B23 313-M-BUS Item number: 002703 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B (1%) kWh; - (2%) kVarh
Tariff registers: 4 (controlled by digital inputs)
Multimeter function (U, I, P, Q, S, PF, f, In)
Limit value monitoring with 2 alarm outputs
Design: top-hat rail
Connection networks: 3×230/400V, 3x400V, 5(65)A
Calibration: MID
Communication: M-Bus (protocol parameterizable) + 2x S0
-
Accuracy class C (0,5%) kWh; - (2%) kVarh
Tariff registers: 4 (controlled by digital inputs)
Multimeter function (U, I, P, Q, S, PF, f, In)
Limit value monitoring with 2 alarm outputs
Design: top-hat rail
Connection networks: 1(6) A, 3×230/400V; 3x400V
Calibration: MID
Communication: Impulse (2x S0)
-
B24 351-IMPULS Item number: 002704 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class C (0,5%) kWh; - (2%) kVarh
Tariff registers: 4 (controlled by digital inputs)
Multimeter function (U, I, P, Q, S, PF, f, In)
Limit value monitoring with 2 alarm outputs
Design: top-hat rail
Connection networks: 1(6) A, 3×230/400V, 3x400V
Calibration: MID
Communication: Impulse (2x S0)
-
B24 352-MODBUS Item number: 002705 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class C (0,5%) kWh; - (2%) kVarh
Tariff registers: 4 (controlled by digital inputs)
Multimeter function (U, I, P, Q, S, PF, f, In)
Limit value monitoring with 2 alarm outputs
Design: top-hat rail
Connection networks: 1(6) A, 3×230/400V, 3x400V
Calibration: MID
Communication: RS485 (Modbus RTU) + 2x S0
-
B24 353-M-BUS Item number: 002706 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class C (0,5%) kWh; - (2%) kVarh
Tariff registers: 4 (controlled by digital inputs)
Multimeter function (U, I, P, Q, S, PF, f, In)
Limit value monitoring with 2 alarm outputs
Design: top-hat rail
Connection networks: 1(6) A, 3×230/400V, 3x400V
Calibration: MID
Communication: M-Bus (protocol parameterizable) + 2x S0
-
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multi measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Integrated web server
Design: top-hat rail
Connection Networks: 3×230/400V
Calibration: MID PTB-A 50.7
Communication: Modbus TCP
-
BME461 CLP Item number: 004872 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multi measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Integrated web server
Design: top-hat rail
Connection networks: 3x 230/400V
Calibration: MID PTB-A 50.7
Communication: Modbus TCP
-
BME461 IMPULS Item number: 003915 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Design: top-hat rail
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID
Communication: Impulse (2x S0)
-
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Design: top-hat rail
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID
Communication: M-Bus (protocol paramentrable)
-
BME461 M-BUS Item number: 003916 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Design: top-hat rail
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID
Communication: M-Bus (protocol paramentrable)
-
BME461 MODBUS Item number: 003917 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Design: top-hat rail
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID
Communication: RS485 (Modbus RTU)
-
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
integrated web server
Design: top-hat rail
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID
Communication: RJ45 – LAN (ModbusTCP, BacNet)
-
BME461 TCP/IP Item number: 003918 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multimeter function (U, I, P, Q, S, PF, f, THD U, THD I, In)
integrated web server
Design: top-hat rail
Connection Networks: 5(80)A, 3×230/400V
Calibration: MID
Communication: RJ45 – LAN (ModbusTCP, BacNet)
-
BME462 CLP Item number: 004873 Four-quadrant measurement (+kWh,-kWh,+kVark,-kVarh)
Accuracy class B(1%) kWh; - (2%) kVarh
Tariff registers: 8 (4 digital and 4 controlled by software)
Multi measurement function (U, I, P, Q, S, PF, f, THD U, THD I, In)
Integrated web server
Design: top-hat rail
Connection Networks: 3×230/400V
Calibration: MID PTB-A 50.7